Building Structure
STRUCTURE SYSTEM
Conventionally reinforced
Concrete frame
STRUCTURAL CAPACITY LIVE LOADS
ROOF | 30 PSF
OFFICE | 50 PSF
PARKING | 50 PSF
CORRIDORS | 100 PSF
MECHANICAL | 125 PSF
STORAGE | 125 or 150 PSF
COMPUTER | 125 PSF
HIGH DENSITY FILES | 250 PSF
COLUMN SPACING
30’x30’ perimeter wall bays
25’x25’ interior core bays
CEILING HEIGHT
10’-6” slab to slab
Access Control
PERIMETER
Perimeter access control systems monitored by Siemens
STRUCTURAL ENGINEER
Haynes Whaley Associates
PLUMBING
Two domestic and sanitary riser columns are provided on each office level floor
HVAC
Central plant two-pipe system, centrifugal chillers, cooling towers, air handling units, PIU on each floor
CONTROLS
Automated, pneumatic and digitally controlled EMS
CAPACITY
400 SF/ton
FRESH AIR
20 CFM/person
ELECTRICAL
SERVICE
277/480-volt, 3-phase, 4-wire dual switches (3,000 and 2,000 amps)
LIFE SAFETY/EMERGENCY GENERATOR
505 KW
FIRE & LIFE SAFETY
Fully automated sprinkler system featuring standpipe riser and upturned sprinkler heads.
Fully supervised automated fire alarm system, manufactured by Notifier. Located in the control in the fire control room next to the main lobby. The alarm system is fully addressable and includes pull stations, smoke and heat detectors, flow switches, tamper switches and audio visual devices